Well.. I'd searched for this manual and although I found many copies online I was pleased to find your website with a well balanced pricing system and easy to search and follow links. That together with the very quick response time was just what I was looking for.. being a very impatient tech.. ;-) I had the service manual in front of me within a short time.
Bookmarked.. and you can bet I will always come here first for my service & user manuals..
best regards
Ed(Tony) Foley
G7WHK
The service manual when downloaded and printed out was clear and easy to read. I would have liked to have been able to enlarge some details, but this was not possible as the file permissions did not allow this. The service was very good. The time taken from placing my order to downloading the document was only a few minutes.
Text excerpt from page 26 (click to view)
AV-20D303
ADJUSTMENT OF PURITY / CONVERGENCE
PURITY ADJUSTMENT
1. Demagnetize CRT with the demagnetizer.
W EDGE DEF LECT ION YOKE
P
2. Loosen the retainer screw of the deflec tion yoke.
3. Remove the wedges.
CR T
4. Input a green raster signal from the signal generator, and turn the screen to green raster.
46
5. Move the deflection yoke backward.
P/C MAGNET S
6. Bring the long lug of the purity magnets on the short lug and position them horizontally. (Fig.2)
# P/C MAGNETS P : PURITY MAGNET 4 : 4 POLES (convergence magnets) 6 : 6 POLES (convergence magnets) Fig.1
7. Adjust the gap between two lugs so that the GREEN RASTER will come into the c enter of the screen. (Fig.3)
8. Move the deflection yoke forward, and fix the pos ition of the deflection yoke so that the whole screen will bec ome green.
9. Ins ert the wedge to the top side of the deflection yoke so that it will not move. 10. Input a cross hatch signal.
Long lug
PURIT Y MAGNET S
11. Verify that the screen is horizontal.
Short lug
12. Input red and blue raster signals, and make sure that purity is properly adjusted.
Bring the long lug over the short lug and position them horizontally.