Who's Online
There currently are 5854 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
I ordered this manual sometime in the afternoon and I received it on my e-mail the same evening.
This is a fantastically good and properly scanned copy of the original manual. All pages are of the same scale and they overlap each other. It means that you can print the manual and easily make it as a convenient paper manual.
The content of the manual is fantastic. Alignment descriptions, PCB layouts and elementary diagrams are explicit and precise. I immediately found what I was looking for. Thanks to this manual and Owner-Manuals.com my amplifier is alive again. Many thanx indded!
;
The manual was well-scanned and easy to read. As an added bonus, the Operator's Manual was bundled with the Service Manual!
I'd definitely use owner-manuals.com again.
;
Finally, i found one website, where i can download this service manual , and fix my hifi. The service manual is very good, and easy to download and to print.
;
Complete and very useful. Could have benefited from a little higher resolution on the schematic and layout diagrams for improved legibility.
;
Great Service Manual, Very Complete, as advertised, Perfect, Thanks!
4.6.9 PURITY AND CONVERGENCE
!PURITY ADJUSTMENT
Note: The final adjustment of CONVERGENCE must be done after the FOCUS adjustment. (CONVERGENCE is changed by FOCUS adjustment.) When makes difference by FOCUS adjustment, should be reconfirming PURITY adjustment. (1) (2) (3) (4) Demagnetize CRT with the demagnetizer. Loosen the retainer screw of the deflection yoke. Remove the wedges. Input a green raster signal from the signal generator, and turn the screen to green raster. (5) Move the deflection yoke backward. (6) Bring the long lug of the purity magnets on the short lug and position them horizontally. (Fig. 2) (7) Adjust the gap between two lugs so that the GREEN RASTER will come into the centre of the screen. (Fig. 3) (8) Move the deflection yoke forward, and fix the position of the deflection yoke so that the whole screen will become green. (9) Insert the wedge to the top side of the deflection yoke so that it will not move. (10) Input a crosshatch signal. (11) Verify that the screen is horizontal. (12) Input red and blue raster signals, and make sure that purity is properly adjusted.
CRT
WEDGE DEFLECTION YOKE
P
46
P/C MAGNETS
� P/C MAGNETS P : PURITY MAGNET 4 : 4 POLES (convergence magnets) 6 : 6 POLES (convergence magnets)
Fig. 1
PURITY MAGNETS Long lug
Short lug Bring the long lug over the short lug and position them horizontally.
Fig. 2
(FRONT VIEW)
GREEN RASTER
CENTRE
Fig. 3