Who's Online
There currently are 5796 guests and 4 members online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
I'm very happy that you all are performing an incredible good job. Furthermore what you did is very useful for all people as me that have electronics as an hobby.Thank you!!!!!
;
Manual found fast and good quality, very helpfull service
;
8-17-12 Been using the sight for about 6 months. Fast Downloads and top quality
Manuels !
;
Everything was great, the manual, the response time, the simplicity of the order, and the
Price. The only thing that I could possible say on a negative note would be that the manual I ordered was more for a service tech. There were a lot of schematic diagrams that didn't help me solve the problem. However I would order again and recommend the web sight to others.
;
I'd been looking for this manual for awhile. Exactly what I needed - and at an excellant price. Thanks!
3.5.8 Sub DET [HR-S6700KR]
Signal Mode Equipment Adjustment part Specified value Adjustment tool (A) (B) (C) (F) (G) (H) � RF signal (sound carrier: S2) � Tuner � EE � Audio level meter � IC1501 pin 26 � T1501 (SUB DET) � Minimum distortion � LPF (30 kHz), HPF (400 Hz)
3.6 SYSCON CIRCUIT Note: � When perform this adjustment, remove the Mechanism assembly. 3.6.1 Timer clock
Signal Mode Equipment (A) (B) (C) � No signal � EE � Frequency counter � IC3001 pin61 � IC3001 pin24 � C3026 + and � � C3025 (TIMER CLOCK) � 1024.008 ± 0.001 Hz (976.5549 ± 0.0010 µsec)
Measuring point (D)
(1) Set the sound carrier of the RF signal generator to S2. (2) Connect the adjustment tool (H) to the measuring point (D). Then connect the equipment (C) to the adjustment tool (H). (3) Adjust the Adjustment part (F) so that the distortion level of the measuring point (D) becomes the specified value (G). 3.5.9 Pilot VCO [HR-S6700KR]
Signal Mode Equipment (A) (B) (C) � No signal � Tuner � EE � Frequency counter � IC1501 pin 11 � C1510 (+) terminal � C1510 (�) terminal � VR1502 (PILOT VCO) � 210 ± 5 Hz
Measuring point (D1) Short point (D2) (D3) Adjustment part (F) Specified value (G)
Measuring point (D1) Short point (D2) (D3) Adjustment part Specified value (F) (G)
(1) Connect the frequency counter to the measuring point (D1). (2) Connect the short wire between the short point (D2) and Vcc (5V). (3) Short the leads of capacitor (D3) once in order to reset the microprocessor of the SYSCON. (4) Disconnect the short wire between the short point (D2) and Vcc then connect it again. (5) Adjust the Adjustment part (F) so that the output frequency becomes the specified value (G).
(1) Connect the short wire between the short points (D2) and (D3). (2) Connect the equipment (C) to the measuring point (D1). (3) Adjust the Adjustment part (F) so that the frequency of the measuring point (D1) becomes the specified value (G). (4) Disconnect the short wire between the short points (D2) and (D3). 3.5.10 Separation [HR-S6700KR]
Signal Mode Equipment Adjustment part Specified value Adjustment tool (A) (B) (C) (F) (G) (H) � Sweep generator output (90 dB, 1 kHz) � EE � Oscilloscope � IC1501 pin 19 � VR1501 (SEPARATION) � Minimum level � Sweeper probe (See Fig. 3-5-10a.)
Measuring point (D)
Shorter than 8 cm
Shield
C : 1000 P R : 75� Earth
Out
Shorter than 5 cm
Fig. 3-5-10a
Sweeper probe
(1) Use the adjustment tool (H), supply 1 kHz R-only modulated IF signal to IF terminal of U/V tuner (front end). (2) Connect the equipment (C) to the measuring point (D). (3) Adjust the Adjustment part (F) so that the output level of the measuring point (D) becomes the specified value (G). 3-7
|
|
|
> |
|