Who's Online
There currently are 5307 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This is a good quality scan of the service manual which includes an assembly diagram, block diagram, schematic, and parts list. Exactly what is needed to repair my KR-V55R receiver.
;
Excellent concise manual. All needed information was included. Typeface and diagrams were clear. Very fair price considering what others are charging. Many thanks
;
Response is a little slow- I had to wait 12 hours to receive download link but it says that it may take up to 24hrs.
Manual is old and was not produced in PDF- scanned copy is exellent.
Overall- value for money- I recommend
;
Excellent quality and quickly delivered manuals at a fair price. Great care is taken in the reproduction process. Even photographs and highly detailed drawings are as clear as in the original. That cannot be said for some freelance manual copies I have obtained from the web. If you have exhausted your internet search of technical manuals, try Owner-Manuals.com. If they do not have it, I do not think it exists. Perhaps, if requested, they may be able to find it. Their resources are certainly greater than most. Shopping here certainly beats waiting for months or years for the manual you seek to appear in an internet auction or garage sale.
;
Very detailed product, also it is a scanning from original, very useful if you have to service this type of amplifier ! Very good product, very hard to find!
3.2 Mechanism compatibility adjustment Notes: � Although compatibility adjustment is very important, it is not necessary to perform this as part of the normal servicing work. It will be required when you have replaced the A/C head, drum assembly or any part of the tape transport system. � To prevent damaging the alignment tape in the compatibility adjustment, prepare a cassette tape (for self-recording/playback), perform a test on it by transporting it and making sure that the tape is not bent by the tape transport mechanisms such as in the guide rollers.(See Fig.3-2-2a.) 3.2.1 Tension pole position Notes: � This adjustment must be performed every time the tension band is replaced.
Signal Mode (A) (B1) (B2) Adjustment part Specified value (F) (G)
3.2.2 FM waveform linearity
Signal Mode Equipment Measuring point External trigger Adjustment part Specified value Adjustment tool (A1) (A2) (B) (C) (D) (E) (F) (G) (H)
� Alignment tape(SP, stairstep, NTSC) [MHP] � Alignment tape(EP, stairstep, NTSC) [MHP-L] � PB � Oscilloscope � TP106 (PB. FM) � TP111 (D.FF) � Guide roller [Mechanism assembly] � Flat V.PB FM waveform � Roller driver [PTU94002]
� Back tension cassette gauge
[PUJ48076-2] � PB
� Eject end � Adjust pin [Mechansim assembly] � 25 - 51 gf�cm (2.45 � 5 � 10-3 Nm)
(1) Play back the back tension cassette gauge (A). (2) Check that the indicated value on the left side gauge is within the specified value (G). (3) If the indicated value is not within the specified value (G), perform the adjustment in a following procedure.(See Fig.3-2-1a.) 1) Remove the top frame, cassette holder and side frames (L/R) all together. (See �section 2 mecha-nism�.) 2) Rotate the loading motor gear to move the control plate so that the triangular stamping to the left of the �P� stamping is aligned with the stamping (a) on the main deck. This positioning is mode (B1). 3) Adjust by turning the adjustment pin so that the tip of the tension arm is aligned with the stamping (b) on the main deck. 4) Rotate the reel disk (S) by about one turn clockwise and make sure that the round hole of the adjustment pin is located in the �OK� range. If it is outside this range, restart the adjustment from the beginning. After completion of the adjustment, rotate the loading gear motor to return it to the mode (B2) position.
TENSION ARM
(1) Play back the alignment tape (A1). (2) Apply the external trigger signal to D.FF (E), to observe the V.PB FM waveform at the measuring point (D). (3) Set the VCR to the manual tracking mode. (4) Make sure that there is no significant level drop of the V.PB FM waveform caused by the tracking operation, with its generally parallel and linear variation ensured. Perform the following adjustments when required. (See Fig. 3-2-2b.) (5) Reduce the V.PB FM waveform by the tracking operation. If a drop in level is found on the left side, turn the guide roller of the pole base assembly (supply side) with the roller driver to make the V.PB FM waveform linear. If a drop in level is on the right side, likewise turn the guide roller of the pole base assembly (take-up side) with the roller driver to make it linear. (See Fig. 3-2-2b.) (6) Make sure that the V.PB FM waveform varies in parallel and linearly with the tracking operation again. When required, perform fine-adjustment of the guide roller of the pole base assembly (supply or take-up side). (7) Unload the cassette tape once, play back the alignment tape (A1) again and confirm the V.PB FM waveform. (8) After adjustment, confirm that the tape wrinkling does not occur at the roller upper or lower limits. (See Fig. 3-2-2a.) [Perform adjustment step (9) only for the models equipped with SP mode and EP (or LP) mode.] (9) Repeat steps (1) to (8) by using the alignment tape (A2).
Improper Proper
(a) GUIDE ROLLER
CONTROL PLATE Stamping(a) Stamping(b) OK
(b) GUIDE POLE
Fig. 3-2-2a
NG ADJUST PIN
Fig. 3-2-1a