Who's Online
There currently are 5966 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
The manual for Sony LBT-D505 component stereo system is was excellent , with schematics, parts layout and parts list as well as instructions for adjustments for each component. Print was clear even when enlarged.
;
It's exactly a complete and very useful manual with all details what I needed. Thank you!I will come back whenever I need your manuals or schematics.
;
I searched EVERYWHERE looking for the manual/s on this "extinct" amp. Owner-Manuals.com made it available and for nearly nothing. Thanx to them, I can decipher the unknown cables and sort them out. Thanx, Owner-Manuals.com!!
;
Yes thank you i got the file i was after. There was a slight problem in my communication but it all worked out well.
A job well done.
;
Great manual...really saved me. The only problem is that I thought I would be able to download it directly when I paid for it but never received the download instructions until the next morning. The board trace pages were somewhat light also: really need to turn up the contrast on the printer before printing them. The schematic page was great; very clear! Well worth the money.
SECTION 4 ADJUSTMENT Please refer to "HR-XVC29SUS No.YD052" about this section except a written item.
4.1 Electrical adjustment (HR-XVC29SUM ONLY) Note: The following adjustment procedures are not only necessary after replacement of consumable mechanical parts or board assemblies, but are also provided as references to be referred to when servicing the electrical circuitry. In case of trouble with the electrical circuitry, always begin a service by identifying the defective points by using the measuring instruments as described in the following electrical adjustment procedures. After this, proceed to the repair, replacement and/or adjustment. If the required measuring instruments are not available in the field, do not change the adjustment parts (variable resistor, etc.) carelessly. 4.1.1 Syscon circuit Notes: � When perform this adjustment, remove the Mechanism assembly. 4.1.1.1 Timer clock
(A1) (B) (C) (D1) (D2) (D3) � � � � � � No signal EE Frequency counter IC3001 pin 29 IC3001 pin 31 IC3001 pin 32
Signal Mode Equipment Measuring point
(D4) � IC3001 pin 25 Adjustment part (F) � C3018 (TIMER CLOCK) Specified value (G1) � 1024.008 ± 0.001 Hz (976.554 ± 0.001 µsec)
(1) Connect the frequency counter to the measuring point (D1). (2) Connect the short wire between the short point (D2) and (D3) to GND. (3) Short the point (D4) and GND in order to reset the microprocessor of the Syscon. (4) Disconnect the short wire between the short point (D3) and GND. (5) Adjust the Adjustment part (F) so that the output frequency becomes the specified value (G).
SECTION 5 TROUBLESHOOTING Please refer to "HR-XVC29SUS No.YD052" about this section.
1-4 (No.YD071)
|
|
|
> |
|